Computer-Controlled Vibrating Tube Densimeter for Liquid Density Measurement in a Wide Temperature and Pressure Range

Author(s):  
E. C. Ihmels ◽  
C. Aufderhaar ◽  
J. Rarey ◽  
J. Gmehling
1979 ◽  
Vol 44 (2) ◽  
pp. 295-306 ◽  
Author(s):  
Ivan Cibulka ◽  
Vladimír Hynek ◽  
Robert Holub ◽  
Jiří Pick

A digital vibrating-tube densimeter was constructed for measuring the density of liquids at several temperatures. The underlying principle of the apparatus is the measurement of the period of eigen-vibrations of a V-shaped tube; the second power of the period of the vibrations is proportional to the density of the liquid in the tube. The temperature of the measuring system is controlled by an electronic regulator. The mean error in the density measurement is approximately ±1 . 10-5 g cm-3 at 25 °C and ±2 . 10-5 g cm-3 at 40 °C. The apparatus was used for an indirect measurement of the excess volume, tested with the benzene-cyclohexane system and further used for determining the excess volume of the benzene-methanol, benzene-acetonitrile and methanol-acetonitrile systems at 25 and 40 °C.


MAPAN ◽  
2021 ◽  
Author(s):  
Jintao Wang ◽  
Xiang Liu ◽  
Wencai Shi ◽  
Changhong Xu

AbstractHydrometers are widely used in industry for liquid density measurement. It is important to achieve rapid and high accuracy calibration for hydrometers. Based on the Archimedes principle, a fully automatic hydrometer calibration system in NIM was designed using Cuckow’s method. The liquid density of n-tridecane (C13H28)is calibrated with 441 g high-purity fused silica ring as the solid density standard. The buoyancy of hydrometer is measured by static weighing system with resolution 0.01 mg. The alignment between liquid surface and hydrometer scale was achieved by the lifting platform with the positioning accuracy of 10 μm. According to the weighing value of hydrometer in air and liquid, the density correction value at different scales is calculated. Hydrometer covering a full range (650–1500) kg/m3can be calibrated without changing the liquid. Taking the calibration data of PTB as reference, the experimental data show that the measurement uncertainty of this system is better than 0.3 division (k = 2).


2017 ◽  
Vol 1 (T1) ◽  
pp. 106-113
Author(s):  
Kien Thach Trung Vo ◽  
Tam Duc Hoang ◽  
Nguyen Hoang Vo ◽  
Chuong Dinh Huynh ◽  
Thanh Thien Tran ◽  
...  

In this work, a gamma scattering technique using 137Cs (5mCi) source with the NaI(Tl) detector is arranged to record the scattered photon beam at scattering angle of 1200 for investigating the liquid density. We used standard liquid such as water, H2SO4, HCl, glycerol, HNO3, ethanol and A92 petrol to fit the single scattering peak, multiple scattering, and total counts versus standard liquid densities. The interpolating of the single scattering peak, multiple scattering, and total counts of the testing sample at scattering angle of 1200 is 0.702 g.cm-3, 0.783 g.cm-3, and 0.747 g.cm-3, respectively. The discrepancy of the experiment and true testing density is about 8 %, 3 %, and 2 %, respectively. The result shows that multiple scattering or total counts can be used to propose the density measurement.


2011 ◽  
Vol 225 (11-12) ◽  
pp. 1271-1291 ◽  
Author(s):  
Claudia Kappler ◽  
Judit Zádor ◽  
Oliver Welz ◽  
Ravi X. Fernandez ◽  
Matthias Olzmann ◽  
...  

2021 ◽  
Vol 56 (3) ◽  
pp. 035026
Author(s):  
Milan S Kovačević ◽  
Marko M Milošević ◽  
Željko M Cimbaljević

2020 ◽  
Vol 18 (12) ◽  
pp. 889-893
Author(s):  
Kalyan Biswas

In this work, a simple but versatile sensing system for very accurate sensing of liquid level and liquid density is presented. The sensor works based on basic strain sensitivity of Fiber Bragg Grating (FBG) and principle of liquid obeying Archimedes’ law of buoyancy. In this system, a cylindrical shaped mass suspended from a Fiber Bragg Grating and partially immersed in the liquid to be sensed. If the liquid level in the container or liquid density varies, that change the up thrust on the suspended mass and load on the Fiber will be changed accordingly. The change in the load on Fiber changes strain on the FBG and the reflected Bragg wavelength also changes. The proposed device with proper calibration should be able to carry out real time and nonstop liquid level and liquid density measurements. A mathematical analysis of the system considering liquid properties and geometrical structure of the suspended mass is presented here. Sensitivity of the system for liquid level monitoring is also reported. Achieved results shows the path for the utilization of the proposed sensor system for precise liquid density measurement and liquid level sensing in very large storage tanks used for commercial/residential applications.


1977 ◽  
Vol 55 (11) ◽  
pp. 2211-2216 ◽  
Author(s):  
S. Hahne ◽  
P. Krebs ◽  
U. Schindewolf

The electrical conductivity of metal–ammonia solutions can be described by an equilibrium of solvated electrons of low mobility and of free electrons of high mobility. With proper choice of the equilibrium constant and its temperature and pressure dependence and of the solvation number of the solvated species the experimental conductivities can be matched in the temperature and pressure range from 240 to 420 K and up to 1000 bar over the entire concentration range from 0.1 mol/ℓ to saturation, also fitting the extrema of the temperature and pressure coefficients of the conductivity around 1 mol/ℓ.


2013 ◽  
Vol 19 (3) ◽  
pp. 389-398 ◽  
Author(s):  
Hadi Baseri ◽  
Ali Haghighi-Asl ◽  
Nader Lotfollahi

In this paper, Peng Robinson equation of state is used for thermodynamic modeling of the solubility of various solid components in the supercritical carbon dioxide. Moreover, the effects of three mixing rules of Van der Waals mixing rules, Panagiotopoulos and Reid mixing rules and modified Kwak and Mansoori mixing rules on the accuracy of calculation results were studied. Good correlations between calculated and experimental data were obtained in the wide temperature and pressure range. A comparison between used models shows that modified Kwak and Mansoori mixing rules give better correlations in comparison with the other mixing rules.